Product Installation / Security Systems

             DEVICE / ADDITIONAL DEVICE                  CONNECTION AND INSTALLATION INSTRUCTIONS

 

The system you have purchased is a device planned to protect your home and workplaces, and works 7/24 as day or night. The device works with motion sensors, panic button and remote control connected to it. The device works in two modes (DAY and NIGHT). Device can fill an area with fog for 15 seconds in one activation and has the capability to cover at least 50-75 m2 area. Between 1 and 10 motion detector (pır) can be connected to the device. Several panic buttons can be connected at the same time. The device’s tank is 500ml volume and for 3 uses. the fog security system is effective in larger m2 areas by adding additional devices.

DEVICE PROMOTION

  • Unpack the device. 
  • Take the dowels which is hanger apparatus and screws (8 mm).
  • Mark the three holes parallel to the ground by leaning the hanger apparatus where you want to install the device.
  • Perforate the places marked on the wall with an 8-bit drill.
  • Tuck in three dowels into the place where you perforate.
  • Fasten the hanger apparatus to the wall with screws.
  • Open the container lid of the device with the help of a funnel and fill it with a gap of approximately 1 cm from the top and close the lid without any foreign matter falling into the reservoir..
  • Slot the hanging place at the back of the device to the hanger apparatus that we hang on the wall.
  • Connect the devices (motion detector, external siren, panic button) that you want to connect with the green connector in the box of the device as shown in the diagram and insert it to its place under the device. (as shown in the connection diagram).
  • Power cable is inside the device , first insert the end of the power cable (220 V plug) into the input under the device , later the other end to a 220V socket.
  • Turn the switch with “1-0” position under the device (ON/OFF) to position 1(ON).

CHEMICAL FILLING AND CONTROL 

  • Fill the fog liquid with the help of a funnel until it approximately 1 cm without cause of overflow, taking the hose out by opening the cover counterclockwise.
  • Close the lid by turning it clockwise.
  • It can be controlled by looking from the resevoir control point on the left side of the device for control the depot in the device or by opening the resevoir lid, it can be controlled by looking from the top.

 

 

LCD PROMOTION

           The screen consists of two lines;

  • Text types(company name) appear on the first line.
  • In the second line, appear the ready text of the device and its temperature.

 

 

USE OF CONTROLLER

 The controller is sliding and consists of 4 buttons.

  • (1) / DAY MODE
  • (2) / NIGHT MODE
  • (3) / FOG (TRIGGER)
  • (4) / STOP – CLOSE

SIREN AND ADDITIONAL DEVICE CONNECTIONS

Quintette connectors come with your device, the connection ways from the right side of the connectors are following ;

  • (-) end connections coming from the siren should be made to the first way.
  • (+) end connections coming from the siren should be made to the seccond way.
  • (COM) end connections should be made to the third way.
  • (NO) end connections should be made to the 4th and 5th way.

NOT: In some siren models (connections operating without trigger) connect (+) and (-) as shown. In DabSİS Security System (+ / +), the one from the siren(-/NO) is connected.

MOTION DETECTOR (PIR) CONNECTIONS

Quart connectors come with your device, the connection ways from the right side of the connectors are following ;

(+) End connections from Motion Detector (PIR) should be made to the first way.

(-) end connections from Motion Detector (PIR) should be made to the second way.

(NO) end connections should be made to the third way.

The (COM) terminal connections from the Motion Detector (PIR) should be made to the 4th way.

PANIC BUTTON CONNECTIONS

 

You can connect any panic button to the system. Connect one of the two ends coming from the panic button to an input of the connector Connect the other end coming from the button to the other input of the connector.

NOTE: You can use the panic button system to connect the dabSIS Security System you have purchased in parallel operation with the alarm systems installed in your workplace or home. In this way, you can trigger in parallel with any kind of alarm system

 

CONNECTION DIAGRAM

Connector inputs;

Siren and Trigger tip must be connected.

Opening and Closing;

After all the connections of the device are maded, leave the button in the “On” section for activate the device

Power input 220V;

Complete the 220V special power cable connectionwhich is sending with the purchased product. For device cleaning and care, first set this button to “Off” position.

HANGING APPARATUS

  •  Lean the hanging apparatus where you will be installing.
  •  Mark the dotted places. 
  •  Perforate the places marked on the wall with an 5-bit drill and insert the dowels.
  •  Screw the hanging apparatus.

 

CARE AND CONTROL

The device should be controlled daily.

  • Lean the hanging apparatus where you will be installing and mark the dotted places.
  • Control the device defect warning light daily.
  • Control the device modes (Day / Night), LED (On-Off / Ready) LCD display and command.
  • Check the device tank fullness.
  • Turn off the device completely for at least 1 hour once a week.
  • The device should be cared by technical service personnel for once every 6 months.
  • Activate the device for fog out section cleaning with letting the fog chemical out one in 15 days.

NOTE: Do not use chemical products out of the fog chemical (DragonFog) produced by our company.


Are you having problems!

If you are having trouble following the installation and additional device assembly instructions, please contact us.

    İzin verilmiyor!